Exit Door Panic Hardware Requirements
Hardware consisting of bars that extend to at least half of the width of the door leaf.
Exit door panic hardware requirements. Codes to know for panic hardware where panic hardware is required the actuating portion of the device touchpad or crossbar must be at least half the. Exit devices are required by building code and local fire departments for many public buildings. An applied force of 15 pounds should be enough to release the latch. Panic hardware used on balanced doors must be touchpad type and the touchpad must not extend more than half.
Above all equip doors with panic hardware and fire exit hardware. 1910 36 d 1 employees must be able to open an exit route door from the inside at all times without keys tools or special knowledge. Force required to operate. Buildings will not pass inspection if they are not up to the life safety code with door hardware.
Some codes and standards require panic hardware to operate. Panic hardware is an exit device which is tested for u. The maximum unlatching force shall not exceed 15 pounds. An exit door must be unlocked.
The actuating portion of the exit device needs to be at least half the width of the actual door. 1 panic hardware shall cause the door latch to release when a force not exceeding 15 pounds is applied to the releasing device in the direction of exit traffic. A force of 15 pounds applied to the touch pad or cross bar must release the latch. A device such as a panic bar that locks only from the outside is permitted on exit discharge doors.
The actuating portion of the panic device must be at least half the width of the door. Because of its durability and ease of use panic hardware is also commonly installed in places where it isn t required by code. When panic hardware. Other requirements for panic hardware include.
Panic hardware and fire exit hardware are two different types of exit devices and the proper selection is determined by code requirements. You should never add a chain lock padlock an extra deadbolt or any electric latches or components that would delay the opening of an egress panic hardware equipped door. However some codes have recently. Such device must be a minimum of one half the width of the door in length.
For example this should not be less than 30 inches and not more than 44 inches above the floor. Current codes require panic hardware to be mounted between 34 inches and 48 inches above the floor. Panic hardware door latching assembly incorporating a device which releases the latch upon application of a force in the direction of exit travel. 2 hand activated door opening hardware shall be centered between 30 inches and 44 inches above the floor.