Exit Door Hardware Requirements
Panic hardware used on balanced doors must be touchpad type and the touchpad must not extend more than half.
Exit door hardware requirements. The actuating portion of the panic device must be at least half the width of the door. Educational occupancies with an occupant load of 50 people or more. Any projection from the ceiling must not reach a point less than six feet eight inches 2 0 m from the floor. It is a requirement for any area in a building to have at least 2 means of emergency exit.
An exit route must meet minimum height and width requirements. Note that these requirements only apply to doors that lock or latch. You should never add a chain lock padlock an extra deadbolt or any electric latches or components that would delay the opening of an egress panic hardware equipped door. The nfpa emergency exit door requirements layout.
The force required to operate the door shall not exceed 30 pounds 133 n to set the door in motion. Access to an. Codes to know for panic hardware. It should not require more than 15 pounds of force to unlatch it.
The door shall be openable with a force not to exceed 15 pounds 67 n when a force of 250 pounds. Assembly occupancies with an occupant load of 50 people or more. The exits must not be. The minimum number of exits from any location in a building is two.
The actuating portion of the exit device needs to be at least half the width of the actual door. The maximum unlatching force shall not exceed 15 pounds. High hazard occupancies with any occupant load. Required number of means of egress.