All streets shall be constructed pursuant to standards.
Eagle mountain standard drawings curb gutter. O 03 2010 1 exh. Plan and profile of all new and existing storm drains and storm manholes and boxes. Eagle mountain city fire chief or his her designee. B to be used with pcc pavement and drives first joint in cases where the 3 min.
The city will be present d. Percent of grade shall also be shown on straight grades with elevations at approximately fifty 50 foot intervals with flow arrows to indicate the direction of drainage. Eagle mountain city 2 3 september 2015 construction and development standards 2 120. All meter setters shall have dual check valves.
The minimum grade for curb and gutter shall be one half 0 5 percent identified on all curb returns and cross gutters. O 13 2015 1 exh. Meter boxes shall be placed between the sidewalk line and property line with combination curb gutter and sidewalk or in the planter if available so that a fence may be placed on property without interfering with the. A mountable curb gutter type 1 sec.
All curbs and gutters and cross gutters will have a flow test prior to final inspection to determine any low or high spots. O 02 2020 2 exh. On radii in the price bid for curb and gutter type 1. We proud to do have a 10 discount for military fire fighters doctors nurses police enforcement we are proud to be with you in your fight against the nationally covid 19 in this process we would like to express our gratitude to our fighters working in the entire healthcare america is proud of you at eagle gutter md we pride our company on reliability great communication integrity.
The city has adopted a publication titled eagle mountain city construction specifications and standards the provisions standards and specifications found in this manual and as amended in the future are hereby incorporated herein by reference. A curb gutter type 1 sec. Storm box and manhole size location and elevations of flow lines and rim. With the apwa standard specifications as amended by the city.
Sumps shall have eccentric lids to ensure adjustments in alignment. Curb gutter type 1 sec. O 21 2016 2 exh. Sumps may only be constructed of reinforced concrete precast sections and shall meet the requirements of astm c478 73 in accordance with standard detail drawings s 15 s 16 and s 17.
B mountable curb gutter type 1 sec. 16 35 030 eagle mountain city construction specifications and standards. O 13 2015 1 exh. All forms or string lines must be inspected by eagle mountain city before concrete may be poured.